Record the cell salvage system, also known as the autotransfusion device, with its make, model, serial number, and location.
Confirm the unit is on the device register and within its service interval.
Inspect the collection reservoir and mounting for cracks and secure fit.
Confirm the correct disposable reservoir is available and in date.
Confirm the suction reaches and holds the recommended vacuum for salvage.
Check suction tubing and the wound suction line are clear and leak-free.
Inspect all tubing and connectors for cracks, kinks, and secure fit.
Confirm no leaks along the fluid path.
Confirm the centrifuge or processing bowl spins smoothly and seats correctly.
Verify the wash and concentration cycle completes correctly.
Confirm the correct filters are fitted, in date, and unblocked.
Replace filters that are damaged or expired.
Confirm the anticoagulant line and drip rate operate where applicable.
Check the anticoagulant solution is correct and in date.
Confirm the display, controls, and mode selection respond correctly.
Check settings are retained between cycles.
Confirm reservoir-level, bowl, and fault alarms activate on test.
Confirm the system halts safely on an alarm.
Inspect for leaks and physical damage, and confirm disposables and readiness stock are available.
Confirm the unit is cleaned, then record deficiencies and raise a corrective action with owner and due date.
Three steps, about 10 to 20 minutes.
Section by section, one check at a time.
Tap Fail, add a photo, assign who fixes it.
The report is ready the moment you finish.
Paper for a one-off check. The app when every finding needs fixing.
Branded checklist
Customize with your logo and company details.
Quick answer
A cell saver system inspection checklist is the structured inspection used to confirm biomedical equipment is calibrated, electrically safe, and fit for clinical use that healthcare teams use to check the key inspection points, assign owners to any failures, and close them with photo proof. Completed in InspectWrk, it is timestamped, works offline, and exports as an audit-ready healthcare report for NABH, NABL and Bio-Medical Waste Management Rules.
A cell saver system inspection checklist is the structured inspection used to confirm biomedical equipment is calibrated, electrically safe, and fit for clinical use that healthcare teams use to check equipment identification, collection and reservoir components, suction system, tubing and connectors, processing and centrifuge system, and filters, capture photo evidence, and track corrective actions to closure. Its job is to confirm biomedical equipment is calibrated, electrically safe, and fit for clinical use. Inspect a cell-salvage or autotransfusion (cell saver) system: equipment identification, collection and reservoir components, suction system, tubing and connectors, processing and centrifuge system, filters, anticoagulant system, controls and display, alarms, and leaks and physical damage, with disposables and maintenance records. It is sometimes called the Cell Saver Inspection Checklist or the Cell Salvage Machine Inspection Checklist.
Biomedical engineering teams still miss out-of-calibration devices, failed leakage or earth test and flat batteries or silenced alarms when rounds are ticked without calibration label photo, safety-test reading and asset tag photo.
Without inspection records, teams reconstruct the evidence from phones instead of proving NABH, NABL and Bio-Medical Waste Management Rules readiness.
It helps infection control nurses and supervisors keep healthcare work consistent, safe, and auditable, with the evidence needed for NABH, NABL and Bio-Medical Waste Management Rules:
A complete cell saver system inspection checklist works through equipment identification, collection and reservoir components, suction system, tubing and connectors, processing and centrifuge system, and filters, then records inspection context, scored checkpoints, and evidence with corrective actions:
Record where and when the inspection runs:
Define what each checkpoint verifies and how results are scored:
Make every finding traceable and actionable:
Follow these steps to run the cell saver system inspection checklist:
See how this checklist fits into Healthcare inspection software.
This checklist runs as a mobile inspection app that works fully offline on site, with AI-powered defect detection on every photo. To see it on your own workflows, talk to our team.
Submit an inspection and AI writes the PDF report and Excel sheet for you. No admin, no waiting.
Your inspector takes a photo of any asset or defect. AI reads it and fills the inspection form automatically.
No typing. No manual entry.
Inspectors speak their observations in any language. AI transcribes and fills the form in real time.
Completely hands-free in the field.
The moment an inspection is submitted, AI summarises the findings and builds a branded PDF report and an Excel sheet for you.
No manual reporting. No copy-paste.
InspectWrk integrates with the tools your team already uses, including Zoho, Microsoft 365, and SAP.
No double entry.
Your operations team sees completion rates, open issues, and compliance scores across all sites in real time.
No chasing updates.
See which checklists your team has in progress across every site, jump into the same inspection with one tap, and keep field, supervisor, and back-office views in sync without sending screenshots on WhatsApp.
Every team reports differently. Build the report your operations, quality, or compliance leads actually want to read, share it as a branded PDF, and schedule delivery to the stakeholders who need it.
See completion, pass rate, and recurring findings across every checklist and every site, without pulling spreadsheets together at the end of the month.
See this checklist running on your own sites in a 30-minute demo.
Book a Free DemoIt is scoped to the scheduled cadence and controls that infection control nurses, biomedical engineers, facility managers, NABH coordinators run, not a one-off handover walk. It prompts equipment identification, collection and reservoir components, suction system, tubing and connectors, processing and centrifuge system, and filters, watching for out-of-calibration devices, failed leakage or earth test and flat batteries or silenced alarms, records pass, fail, or N/A with calibration label photo, safety-test reading and asset tag photo on critical items, and raises corrective actions with owners before sign-off. Run in InspectWrk, the record is timestamped and rolls into trend reports so repeat failures surface before the next audit.
They work through each checkpoint to confirm biomedical equipment is calibrated, electrically safe, and fit for clinical use, confirm the required controls are in place, and capture calibration label photo, safety-test reading and asset tag photo on anything that fails or needs proof. Priority failure modes include out-of-calibration devices, failed leakage or earth test and flat batteries or silenced alarms. Each checkpoint takes pass, fail, or N/A, and a failed item stays open until the fix is verified.
It expects calibration label photo, safety-test reading and asset tag photo, plus inspection records on failed or critical items, so findings rest on proof rather than memory. Records support NABH, NABL and Bio-Medical Waste Management Rules, and every photo, note, and sign-off stays attached to the inspection instead of living in chat threads.
The cell saver system inspection checklist covers equipment identification, collection and reservoir components, suction system, tubing and connectors, processing and centrifuge system, and filters. On each checkpoint, infection control nurses record pass, fail, or N/A, add a photo on anything that needs proof, and raise a corrective action with an owner and due date. Run in InspectWrk, the inspection is timestamped, traceable to whoever completed it, and exports as a single healthcare report aligned to NABH, NABL and Bio-Medical Waste Management Rules.

Test medical-gas alarms: area and master alarms, alarm activation, audible and visual indicators, pressure conditions, sensor response, and panel status, with test results.

Inspect a mechanical ventilator for operational readiness: power supply, battery, self-test, alarm functionality, oxygen and air supply connections, breathing circuit, tubing and connectors, filters, sensors, display, and controls, with cleaning and inspection documentation.
Inspect the autoclave or steam sterilizer as equipment: chamber condition, door, locking mechanism and gasket, pressure and temperature indicators, controls and cycle settings, alarms, water supply and drainage, leaks and corrosion, cycle records, and sterilization indicators.
Inspect a multiparameter patient monitor: display, power and battery, alarm system, ECG leads, SpO2 sensor, blood-pressure cuff, temperature probe, cables and connectors, and controls, with physical-condition checks, cleaning, and functional testing.