Oxygen Concentrator InspectionWard 3 · Equipment Identification0 of 3 checked
  • Record the concentrator make, model, serial number, and hours run.Smiling nurse in scrubs and doctor in a white coat review a tablet by a bedPhoto Added
  • Confirm the unit is on the device register and within its service interval.Smiling nurse in scrubs and doctor in a white coat review a tablet by a bedPhoto Added
  • Inspect the housing, casters, and controls for cracks and damage.Smiling nurse in scrubs and doctor in a white coat review a tablet by a bedPhoto Added
Free on iOS and AndroidGet the App

What’s in this checklist.

10 sections · 20 questions · 10 to 20 minutes · Free

    1. Record the concentrator make, model, serial number, and hours run.

    2. Confirm the unit is on the device register and within its service interval.

    1. Inspect the housing, casters, and controls for cracks and damage.

    2. Confirm labels and warnings are legible.

    1. Confirm the flow control sets and holds the required flow rate.

    2. Verify flow accuracy against the flowmeter or a reference.

    1. Confirm oxygen concentration meets specification using the built-in monitor or an analyzer.

    2. Verify the low-purity indicator or alarm operates where fitted.

    1. Inspect tubing, cannula connection, and the outlet for cracks and secure fit.

    2. Confirm no leaks at the outlet and connections.

    1. Confirm intake and cabinet filters are clean, fitted, and in date.

    2. Clean or replace filters that are dirty or blocked.

    1. Confirm power-loss, low-flow, and low-purity alarms activate on test.

    2. Verify indicator lights operate correctly.

    1. Inspect the power cord and plug for damage and secure connection.

    2. Confirm battery back-up, where fitted, operates.

    1. Confirm the display and controls respond correctly.

    2. Check the hours meter and service reminders.

    1. Confirm the unit is cleaned and disinfected.

    2. Record deficiencies and raise a corrective action with owner and due date.

How the Oxygen Concentrator Inspection checklist works.

Three steps, about 10 to 20 minutes.

  1. Work through each section

    Section by section, one check at a time.

  2. Log every finding

    Tap Fail, add a photo, assign who fixes it.

  3. Sign off and share

    The report is ready the moment you finish.

Same checklist, two ways to run it.

Paper for a one-off check. The app when every finding needs fixing.

Printed PDF

  • Pen on paper
  • Photos in your camera roll
  • Report typed up later

InspectWrk appRecommended

  • Photos on every finding
  • Owner and due date per finding
  • Report ready at sign-off
Get the App

Branded checklist

Get Your Company Branded Checklist

Customize with your logo and company details.

We respect your privacy. No spam, ever.

What is an oxygen concentrator inspection checklist?

Quick answer

An oxygen concentrator inspection checklist is the structured inspection used to confirm biomedical equipment is calibrated, electrically safe, and fit for clinical use that healthcare teams use to check the key inspection points, assign owners to any failures, and close them with photo proof. Completed in InspectWrk, it is timestamped, works offline, and exports as an audit-ready healthcare report for NABH, NABL and Bio-Medical Waste Management Rules.

An oxygen concentrator inspection checklist is the structured inspection used to confirm biomedical equipment is calibrated, electrically safe, and fit for clinical use that healthcare teams use to check equipment identification, housing and physical condition, oxygen output and flow, oxygen concentration and purity, tubing and oxygen outlet, and filters, capture photo evidence, and track corrective actions to closure. Its job is to confirm biomedical equipment is calibrated, electrically safe, and fit for clinical use. Inspect oxygen concentrators for operational readiness: equipment identification, housing and physical condition, oxygen output and flow, oxygen concentration and purity checks where applicable, tubing and oxygen outlet, filters, alarms and indicators, power cord and battery, and display and controls. It is sometimes called the Oxygen Concentrator Maintenance Checklist or the Oxygen Concentrator Safety Checklist.

Why are oxygen concentrator inspections still chased on WhatsApp?

Biomedical engineering teams still miss out-of-calibration devices, failed leakage or earth test and flat batteries or silenced alarms when rounds are ticked without calibration label photo, safety-test reading and asset tag photo.

Without inspection records, teams reconstruct the evidence from phones instead of proving NABH, NABL and Bio-Medical Waste Management Rules readiness.

Before and After InspectWrk

Before InspectWrk

  • Ward rounds, housekeeping audits, and biomedical PPM live in separate paper binders across departments.
  • Oxygen concentrator checks are ticked on paper without photo evidence per finding.
  • NABH auditors find scattered records and missing evidence, surfaced only during the audit itself.

After InspectWrk

  • Infection control nurses complete the inspection in the app with photo evidence at the oxygen concentrator, even offline.
  • Managers see open findings, closure status, and NABH, NABL and Bio-Medical Waste Management Rules evidence live on one dashboard.
  • A failed sterile-zone or biomedical waste check raises a corrective action with an owner before the next audit.

Why is an oxygen concentrator inspection checklist important?

It helps infection control nurses and supervisors keep healthcare work consistent, safe, and auditable, with the evidence needed for NABH, NABL and Bio-Medical Waste Management Rules:

  • Cover the full inspection: structured checks across equipment identification, housing and physical condition, oxygen output and flow, and oxygen concentration and purity surface out-of-calibration devices, failed leakage or earth test and flat batteries or silenced alarms before they reach handover, audit, or the next shift.
  • Document healthcare findings with the right proof: capture calibration label photo, safety-test reading and asset tag photo on every issue so nothing rests on memory.
  • Close healthcare issues instead of just logging them: assign corrective actions with owners and due dates, then verify the fix before sign-off.
  • Stay audit-ready: keep one timestamped record for NABH, NABL and Bio-Medical Waste Management Rules you can export instead of rebuilding it from scattered photos and spreadsheets.

What should be included in an oxygen concentrator inspection checklist?

A complete oxygen concentrator inspection checklist works through equipment identification, housing and physical condition, oxygen output and flow, oxygen concentration and purity, tubing and oxygen outlet, and filters, then records inspection context, scored checkpoints, and evidence with corrective actions:

Inspection context

Record where and when the inspection runs:

  • Site, healthcare location, and asset identification
  • Inspector, date, and the healthcare areas or assets in scope
  • Reference numbers or schedules linked to the checklist

Checkpoints and scoring

Define what each checkpoint verifies and how results are scored:

  • Equipment Identification
  • Housing & Physical Condition
  • Oxygen Output & Flow
  • Oxygen Concentration & Purity
  • Tubing & Oxygen Outlet
  • Filters
  • 11 fields aligned to the checklist

Evidence and corrective actions

Make every finding traceable and actionable:

  • Capture calibration label photo, safety-test reading and asset tag photo on failed or critical items
  • Retain inspection records with the inspection record
  • Sign-off, completion status, and follow-up notes

How do teams use an oxygen concentrator inspection checklist?

Follow these steps to run the oxygen concentrator inspection checklist:

  1. Fill in the oxygen concentrator header: inspector, site, date, and areas in scope.
  2. Work through equipment identification, housing and physical condition, oxygen output and flow, oxygen concentration and purity, tubing and oxygen outlet, and filters in order, recording pass, fail, or N/A.
  3. Attach calibration label photo, safety-test reading and asset tag photo wherever a failure or observation needs proof.
  4. Raise actions for out-of-calibration devices, failed leakage or earth test and flat batteries or silenced alarms with owners and deadlines before sign-off.
  5. Review the oxygen concentrator summary, share the report, and keep the record for your audit trail.

See how this checklist fits into Healthcare inspection software.

This checklist runs as a mobile inspection app that works fully offline on site, with AI-powered defect detection on every photo. To see it on your own workflows, talk to our team.

AI-Powered Features for Your Field Workflows

Submit an inspection and AI writes the PDF report and Excel sheet for you. No admin, no waiting.

01 / 05Photo to formVISION AI

Take a Photo. AI Fills the Form.

Your inspector takes a photo of any asset or defect. AI reads it and fills the inspection form automatically.

No typing. No manual entry.

02 / 05Voice to textVOICE AI

Speak. AI Writes It Down.

Inspectors speak their observations in any language. AI transcribes and fills the form in real time.

Completely hands-free in the field.

03 / 05Auto reportsREPORT AI

AI Writes the Report. PDF and Excel, Instantly.

The moment an inspection is submitted, AI summarises the findings and builds a branded PDF report and an Excel sheet for you.

No manual reporting. No copy-paste.

04 / 05IntegrationsINTEGRATIONS

Connect Your Existing Tools.

InspectWrk integrates with the tools your team already uses, including Zoho, Microsoft 365, and SAP.

No double entry.

05 / 05Live dashboardLIVE DATA

Live Dashboard. Every Site. Always On.

Your operations team sees completion rates, open issues, and compliance scores across all sites in real time.

No chasing updates.

One Platform. Mobile-First. AI-Powered.

  • Collaborate

    Collaborate with your team anytime, anywhere

    See which checklists your team has in progress across every site, jump into the same inspection with one tap, and keep field, supervisor, and back-office views in sync without sending screenshots on WhatsApp.

    • Organise inspection data by site, team, and date
    • Assign checks to the inspector or vendor responsible
    • Track completion across every location in one view
    • Keep field and back-office in sync in real time
    • Comment on findings without leaving the inspection
  • Custom Reports

    Custom reports that guide your decision making

    Every team reports differently. Build the report your operations, quality, or compliance leads actually want to read, share it as a branded PDF, and schedule delivery to the stakeholders who need it.

    • Branded PDF and CSV export from any completed inspection
    • Schedule weekly or monthly delivery to managers and clients
    • Share to email, Drive, Teams, or Slack in one click
    • Filter findings by site, severity, or corrective-action status
  • Powerful Analytics

    Analyse your inspection data with confidence

    See completion, pass rate, and recurring findings across every checklist and every site, without pulling spreadsheets together at the end of the month.

    Powerful dashboard
    Combine multiple reports into one dashboard so you can monitor status, bottlenecks, and completion trends at a glance.
    Always in sync
    Changes sync across devices so inspectors, supervisors, and back-office teams always see the latest responses and attachments.
    Embedded analytics
    Explore checklist data with charts and breakdowns that stay tied to the underlying inspections, without exporting to spreadsheets.

Oxygen Concentrator Inspectionquestions

See this checklist running on your own sites in a 30-minute demo.

Book a Free Demo

It is scoped to the scheduled cadence and controls that infection control nurses, biomedical engineers, facility managers, NABH coordinators run, not a one-off handover walk. It prompts equipment identification, housing and physical condition, oxygen output and flow, oxygen concentration and purity, tubing and oxygen outlet, and filters, watching for out-of-calibration devices, failed leakage or earth test and flat batteries or silenced alarms, records pass, fail, or N/A with calibration label photo, safety-test reading and asset tag photo on critical items, and raises corrective actions with owners before sign-off. Run in InspectWrk, the record is timestamped and rolls into trend reports so repeat failures surface before the next audit.

They work through each checkpoint to confirm biomedical equipment is calibrated, electrically safe, and fit for clinical use, confirm the required controls are in place, and capture calibration label photo, safety-test reading and asset tag photo on anything that fails or needs proof. Priority failure modes include out-of-calibration devices, failed leakage or earth test and flat batteries or silenced alarms. Each checkpoint takes pass, fail, or N/A, and a failed item stays open until the fix is verified.

It expects calibration label photo, safety-test reading and asset tag photo, plus inspection records on failed or critical items, so findings rest on proof rather than memory. Records support NABH, NABL and Bio-Medical Waste Management Rules, and every photo, note, and sign-off stays attached to the inspection instead of living in chat threads.

The oxygen concentrator inspection checklist covers equipment identification, housing and physical condition, oxygen output and flow, oxygen concentration and purity, tubing and oxygen outlet, and filters. On each checkpoint, infection control nurses record pass, fail, or N/A, add a photo on anything that needs proof, and raise a corrective action with an owner and due date. Run in InspectWrk, the inspection is timestamped, traceable to whoever completed it, and exports as a single healthcare report aligned to NABH, NABL and Bio-Medical Waste Management Rules.

More healthcare checklists.

  • Hands typing on a laptop showing pie and bar charts, with a phone and tablet nearby
    Healthcare9,400+ downloads

    Medical Gas Alarm Test Checklist

    Test medical-gas alarms: area and master alarms, alarm activation, audible and visual indicators, pressure conditions, sensor response, and panel status, with test results.

    • Healthcare
    • Medical gas
    Get Checklist: Medical Gas Alarm Test Checklist
  • Worker in yellow hard hat crouching on a rooftop of solar panels while holding a radio
    Healthcare9,400+ downloads

    Ventilator Inspection Checklist

    Inspect a mechanical ventilator for operational readiness: power supply, battery, self-test, alarm functionality, oxygen and air supply connections, breathing circuit, tubing and connectors, filters, sensors, display, and controls, with cleaning and inspection documentation.

    • Ventilator
    • Respiratory
    Get Checklist: Ventilator Inspection Checklist
  • Autoclave, Steam Sterilizer Inspection Checklist checklist in use
    Healthcare9,200+ downloads

    Autoclave, Steam Sterilizer Inspection Checklist

    Inspect the autoclave or steam sterilizer as equipment: chamber condition, door, locking mechanism and gasket, pressure and temperature indicators, controls and cycle settings, alarms, water supply and drainage, leaks and corrosion, cycle records, and sterilization indicators.

    • Autoclave
    • Steam sterilizer
    Get Checklist: Autoclave, Steam Sterilizer Inspection Checklist
  • Patient Monitor Inspection Checklist checklist in use
    Healthcare9,200+ downloads

    Patient Monitor Inspection Checklist

    Inspect a multiparameter patient monitor: display, power and battery, alarm system, ECG leads, SpO2 sensor, blood-pressure cuff, temperature probe, cables and connectors, and controls, with physical-condition checks, cleaning, and functional testing.

    • Patient monitor
    • Multiparameter
    Get Checklist: Patient Monitor Inspection Checklist