InspectWrk

HVAC (School) Daily Inspection Checklist

Use this HVAC (school) daily inspection checklist to check filter condition, coil cleanliness, refrigerant readings and damper operation on education sites so teams can confirm HVAC plant delivers designed airflow, filtration, and refrigerant integrity, logging issues with photos and notes and assigning corrective actions before sign-off. Watch for blocked filters, fouled coils and refrigerant undercharge. Records support ASHRAE 180, F-Gas and TM44.

6 sections20 questions16 to 30 minutesFree

HVAC (School) Daily InspectionBlock A · Inspection Checkpoints0 of 3 checked
  • Filter condition.Three children at a lab table with colored liquids in flasks, two wearing goggles, writing notesPhoto Added
  • Coil cleanliness.Three children at a lab table with colored liquids in flasks, two wearing goggles, writing notesPhoto Added
  • Damper operation.Three children at a lab table with colored liquids in flasks, two wearing goggles, writing notesPhoto Added
Free on iOS and AndroidGet the App

What’s in this checklist.

6 sections · 20 questions · 16 to 30 minutes · Free

    1. Record the site or location, area, and date of this HVAC school.

    2. Record the inspector and the scope or items included in this inspection.

    3. Confirm any relevant reference documents or standards are available.

    1. Filter condition.

    2. Coil cleanliness.

    3. Refrigerant readings.

    4. Damper operation.

    5. Drain pan and condensate.

    1. Check for blocked filters.

    2. Check for fouled coils.

    3. Check for refrigerant undercharge.

    4. Check for stuck dampers.

    1. Capture filter photo.

    2. Capture coil photo.

    3. Capture gauge reading.

    1. Confirm the inspection meets the requirements of ASHRAE 180, F-Gas and TM44.

    2. Confirm records are retained for the required period and available for audit.

    1. Attach photo evidence for every non-compliant finding.

    2. Assign each deficiency to an owner with a corrective action and due date.

    3. Confirm re-inspection requirements are recorded before sign-off.

How the HVAC (School) Daily Inspection checklist works.

Three steps, about 16 to 30 minutes.

  1. Work through each section

    Section by section, one check at a time.

  2. Log every finding

    Tap Fail, add a photo, assign who fixes it.

  3. Sign off and share

    The report is ready the moment you finish.

Same checklist, two ways to run it.

Paper for a one-off check. The app when every finding needs fixing.

Printed PDF

  • Pen on paper
  • Photos in your camera roll
  • Report typed up later

InspectWrk appRecommended

  • Photos on every finding
  • Owner and due date per finding
  • Report ready at sign-off
Get the App

Branded checklist

Get Your Company Branded Checklist

Customize with your logo and company details.

We respect your privacy. No spam, ever.

What is an HVAC (school) daily inspection checklist?

Quick answer

An HVAC (school) daily inspection checklist is the daily round used to confirm HVAC plant delivers designed airflow, filtration, and refrigerant integrity that education teams use to check the key inspection points, assign owners to any failures, and close them with photo proof. Completed in InspectWrk, it is timestamped, works offline, and exports as an audit-ready education report for ASHRAE 180, F-Gas and TM44.

An HVAC (school) daily inspection checklist is the daily round used to confirm HVAC plant delivers designed airflow, filtration, and refrigerant integrity that education teams use to check filter condition, coil cleanliness, refrigerant readings and damper operation, capture photo evidence, and track corrective actions to closure. Its job is to confirm HVAC plant delivers designed airflow, filtration, and refrigerant integrity. Use this HVAC (School) Daily Inspection Checklist to run a daily HVAC PPM round on school HVAC filters, fans, and condensate, mark each point pass or fail with photos, and surface issues before the next class.

Why do daily HVAC (school) checks fail without photo evidence?

HVAC engineers and FM engineering managers still miss blocked filters, fouled coils and refrigerant undercharge when rounds are ticked without filter photo, coil photo and gauge reading.

Without a single inspection record, teams reconstruct the evidence from phones instead of proving ASHRAE 180, F-Gas and TM44 readiness.

Before and After InspectWrk

Before InspectWrk

  • education daily inspections for HVAC (school) happen on paper or in WhatsApp threads, with no timestamp and no photo evidence.
  • PPM contractors self-certify coil cleans without readings or photos on the asset record.
  • You find out about an HVAC (school) issue from a client complaint or an auditor, not from your own team in real time.

After InspectWrk

  • HVAC engineers complete the daily inspection in the app with photo evidence at the HVAC (school), even offline.
  • Managers see open findings, closure status, and ASHRAE 180, F-Gas and TM44 evidence live on one dashboard.
  • Overdue corrective actions escalate automatically so the fix happens before the next education audit.

Why is an HVAC (school) daily inspection checklist important?

It helps HVAC engineers and supervisors keep education work consistent, safe, and auditable, with the evidence needed for ASHRAE 180, F-Gas and TM44:

  • Cover the full inspection: structured checks across filter condition, coil cleanliness, refrigerant readings and damper operation surface blocked filters, fouled coils and refrigerant undercharge before they reach handover, audit, or the next shift.
  • Document education findings with the right proof: capture filter photo, coil photo and gauge reading on every issue so nothing rests on memory.
  • Close education issues instead of just logging them: assign corrective actions with owners and due dates, then verify the fix before sign-off.
  • Stay audit-ready: keep one timestamped record for ASHRAE 180, F-Gas and TM44 you can export instead of rebuilding it from scattered photos and spreadsheets.

What should be included in an HVAC (school) daily inspection checklist?

A complete HVAC (school) daily inspection checklist works through filter condition, coil cleanliness, refrigerant readings and damper operation, then records inspection context, scored checkpoints, and evidence with corrective actions:

Inspection context

Record where and when the inspection runs:

  • Site, education location, and asset identification
  • Inspector, date, and the education areas or assets in scope
  • Reference numbers or schedules linked to the checklist

Checkpoints and scoring

Define what each checkpoint verifies and how results are scored:

  • filter condition
  • coil cleanliness
  • refrigerant readings
  • damper operation
  • drain pan and condensate
  • Failure watchouts: blocked filters, fouled coils and refrigerant undercharge
  • Evidence: filter photo, coil photo and gauge reading
  • 20 fields aligned to the checklist

Evidence and corrective actions

Make every finding traceable and actionable:

  • Capture filter photo, coil photo and gauge reading on failed or critical items
  • Corrective actions with owners and due dates for education teams
  • Sign-off, completion status, and follow-up notes

How do teams use an HVAC (school) daily inspection checklist?

Follow these steps to run the HVAC (school) daily inspection checklist:

  1. Fill in the HVAC (school) header: inspector, site, date, and areas in scope.
  2. Work through filter condition, coil cleanliness, refrigerant readings and damper operation in order, recording pass, fail, or N/A.
  3. Attach filter photo, coil photo and gauge reading wherever a failure or observation needs proof.
  4. Raise actions for blocked filters, fouled coils and refrigerant undercharge with owners and deadlines before sign-off.
  5. Review the HVAC (school) summary, share the report, and keep the record for your audit trail.

See how this checklist fits into Asset inspection software.

This checklist runs as a mobile inspection app that works fully offline on site, with AI-powered defect detection on every photo. To see it on your own workflows, talk to our team.

AI-Powered Features for Your Field Workflows

Submit an inspection and AI writes the PDF report and Excel sheet for you. No admin, no waiting.

01 / 05Photo to formVISION AI

Take a Photo. AI Fills the Form.

Your inspector takes a photo of any asset or defect. AI reads it and fills the inspection form automatically.

No typing. No manual entry.

02 / 05Voice to textVOICE AI

Speak. AI Writes It Down.

Inspectors speak their observations in any language. AI transcribes and fills the form in real time.

Completely hands-free in the field.

03 / 05Auto reportsREPORT AI

AI Writes the Report. PDF and Excel, Instantly.

The moment an inspection is submitted, AI summarises the findings and builds a branded PDF report and an Excel sheet for you.

No manual reporting. No copy-paste.

04 / 05IntegrationsINTEGRATIONS

Connect Your Existing Tools.

InspectWrk integrates with the tools your team already uses, including Zoho, Microsoft 365, and SAP.

No double entry.

05 / 05Live dashboardLIVE DATA

Live Dashboard. Every Site. Always On.

Your operations team sees completion rates, open issues, and compliance scores across all sites in real time.

No chasing updates.

One Platform. Mobile-First. AI-Powered.

  • Collaborate

    Collaborate with your team anytime, anywhere

    See which checklists your team has in progress across every site, jump into the same inspection with one tap, and keep field, supervisor, and back-office views in sync without sending screenshots on WhatsApp.

    • Organise inspection data by site, team, and date
    • Assign checks to the inspector or vendor responsible
    • Track completion across every location in one view
    • Keep field and back-office in sync in real time
    • Comment on findings without leaving the inspection
  • Custom Reports

    Custom reports that guide your decision making

    Every team reports differently. Build the report your operations, quality, or compliance leads actually want to read, share it as a branded PDF, and schedule delivery to the stakeholders who need it.

    • Branded PDF and CSV export from any completed inspection
    • Schedule weekly or monthly delivery to managers and clients
    • Share to email, Drive, Teams, or Slack in one click
    • Filter findings by site, severity, or corrective-action status
  • Powerful Analytics

    Analyse your inspection data with confidence

    See completion, pass rate, and recurring findings across every checklist and every site, without pulling spreadsheets together at the end of the month.

    Powerful dashboard
    Combine multiple reports into one dashboard so you can monitor status, bottlenecks, and completion trends at a glance.
    Always in sync
    Changes sync across devices so inspectors, supervisors, and back-office teams always see the latest responses and attachments.
    Embedded analytics
    Explore checklist data with charts and breakdowns that stay tied to the underlying inspections, without exporting to spreadsheets.

HVAC (School) Daily Inspectionquestions

See this checklist running on your own sites in a 30-minute demo.

Book a Free Demo

It is scoped to the daily cadence and controls that HVAC engineers, FM engineering managers, energy managers run, not a one-off handover walk. It prompts filter condition, coil cleanliness, refrigerant readings and damper operation, watching for blocked filters, fouled coils and refrigerant undercharge, records pass, fail, or N/A with filter photo, coil photo and gauge reading on critical items, and raises corrective actions with owners before sign-off. Run in InspectWrk, the record is timestamped and rolls into trend reports so repeat failures surface before the next audit.

They work through each checkpoint to confirm HVAC plant delivers designed airflow, filtration, and refrigerant integrity, confirm the required controls are in place, and capture filter photo, coil photo and gauge reading on anything that fails or needs proof. Priority failure modes include blocked filters, fouled coils and refrigerant undercharge. Each checkpoint takes pass, fail, or N/A, and a failed item stays open until the fix is verified.

It expects filter photo, coil photo and gauge reading on failed or critical items, so findings rest on proof rather than memory. Records support ASHRAE 180, F-Gas and TM44, and every photo, note, and sign-off stays attached to the inspection instead of living in chat threads.

It checks filter condition, coil cleanliness, refrigerant readings and damper operation across education sites. The round exists to confirm HVAC plant delivers designed airflow, filtration, and refrigerant integrity. It prioritises failure modes such as blocked filters, fouled coils and refrigerant undercharge. HVAC engineers record pass, fail, or N/A on each item, capture photo evidence on anything that needs proof, and assign corrective actions with owners and due dates. Evidence expectations include filter photo, coil photo and gauge reading. A failed item stays open until the fix is verified, and it runs offline so a weak signal never costs a round. Run in InspectWrk, every finding is timestamped and exports as a single education report aligned to ASHRAE 180, F-Gas and TM44.

More education checklists.