Take a Photo. AI Fills the Form.
Your inspector takes a photo of any asset or defect. AI reads it and fills the inspection form automatically.
No typing. No manual entry.
Use this HVAC (school) weekly checklist to inspect filter condition, coil cleanliness, refrigerant readings and damper operation on education sites so teams can confirm HVAC plant delivers designed airflow, filtration, and refrigerant integrity, scoring each item and raising corrective actions with owners and due dates. Watch for blocked filters, fouled coils and refrigerant undercharge. Records support ASHRAE 180, F-Gas and TM44.
6 sections20 questions16 to 30 minutesFree
Photo Added
Photo Added
Photo Added6 sections · 20 questions · 16 to 30 minutes · Free
Record the site or location, area, and date of this HVAC school.
Record the inspector and the scope or items included in this inspection.
Confirm any relevant reference documents or standards are available.
Filter condition.
Coil cleanliness.
Refrigerant readings.
Damper operation.
Drain pan and condensate.
Check for blocked filters.
Check for fouled coils.
Check for refrigerant undercharge.
Check for stuck dampers.
Capture filter photo.
Capture coil photo.
Capture gauge reading.
Confirm the inspection meets the requirements of ASHRAE 180, F-Gas and TM44.
Confirm records are retained for the required period and available for audit.
Attach photo evidence for every non-compliant finding.
Assign each deficiency to an owner with a corrective action and due date.
Confirm re-inspection requirements are recorded before sign-off.
Three steps, about 16 to 30 minutes.
Section by section, one check at a time.
Tap Fail, add a photo, assign who fixes it.
The report is ready the moment you finish.
Paper for a one-off check. The app when every finding needs fixing.
Branded checklist
Customize with your logo and company details.
Quick answer
An HVAC (school) weekly checklist is the weekly walk used to confirm HVAC plant delivers designed airflow, filtration, and refrigerant integrity that education teams use to check the key inspection points, assign owners to any failures, and close them with photo proof. Completed in InspectWrk, it is timestamped, works offline, and exports as an audit-ready education report for ASHRAE 180, F-Gas and TM44.
An HVAC (school) weekly checklist is the weekly walk used to confirm HVAC plant delivers designed airflow, filtration, and refrigerant integrity that education teams use to check filter condition, coil cleanliness, refrigerant readings and damper operation, capture photo evidence, and track corrective actions to closure. Its job is to confirm HVAC plant delivers designed airflow, filtration, and refrigerant integrity. Use this HVAC (School) Weekly Checklist to run a weekly HVAC PPM round on school HVAC filters, fans, and condensate, trend recurring issues, and close open items from the previous week. Run digitally in InspectWrk, every finding is timestamped, photo-evidenced, and traceable to the inspector, with the records education teams need for ASHRAE 180, F-Gas and TM44.
HVAC engineers and FM engineering managers still miss blocked filters, fouled coils and refrigerant undercharge when rounds are ticked without filter photo, coil photo and gauge reading.
Without a single inspection record, teams reconstruct the evidence from phones instead of proving ASHRAE 180, F-Gas and TM44 readiness.
It helps HVAC engineers and supervisors keep education work consistent, safe, and auditable, with the evidence needed for ASHRAE 180, F-Gas and TM44:
A complete HVAC (school) weekly checklist works through filter condition, coil cleanliness, refrigerant readings and damper operation, then records inspection context, scored checkpoints, and evidence with corrective actions:
Record where and when the inspection runs:
Define what each checkpoint verifies and how results are scored:
Make every finding traceable and actionable:
Follow these steps to run the HVAC (school) weekly checklist:
See how this checklist fits into Asset inspection software.
This checklist runs as a mobile inspection app that works fully offline on site, with AI-powered defect detection on every photo. To see it on your own workflows, talk to our team.
Submit an inspection and AI writes the PDF report and Excel sheet for you. No admin, no waiting.
Your inspector takes a photo of any asset or defect. AI reads it and fills the inspection form automatically.
No typing. No manual entry.
Inspectors speak their observations in any language. AI transcribes and fills the form in real time.
Completely hands-free in the field.
The moment an inspection is submitted, AI summarises the findings and builds a branded PDF report and an Excel sheet for you.
No manual reporting. No copy-paste.
InspectWrk integrates with the tools your team already uses, including Zoho, Microsoft 365, and SAP.
No double entry.
Your operations team sees completion rates, open issues, and compliance scores across all sites in real time.
No chasing updates.
See which checklists your team has in progress across every site, jump into the same inspection with one tap, and keep field, supervisor, and back-office views in sync without sending screenshots on WhatsApp.
Every team reports differently. Build the report your operations, quality, or compliance leads actually want to read, share it as a branded PDF, and schedule delivery to the stakeholders who need it.
See completion, pass rate, and recurring findings across every checklist and every site, without pulling spreadsheets together at the end of the month.
See this checklist running on your own sites in a 30-minute demo.
Book a Free DemoIt is scoped to the weekly cadence and controls that HVAC engineers, FM engineering managers, energy managers run, not a one-off handover walk. It prompts filter condition, coil cleanliness, refrigerant readings and damper operation, watching for blocked filters, fouled coils and refrigerant undercharge, records pass, fail, or N/A with filter photo, coil photo and gauge reading on critical items, and raises corrective actions with owners before sign-off. Run in InspectWrk, the record is timestamped and rolls into trend reports so repeat failures surface before the next audit.
They work through each checkpoint to confirm HVAC plant delivers designed airflow, filtration, and refrigerant integrity, confirm the required controls are in place, and capture filter photo, coil photo and gauge reading on anything that fails or needs proof. Priority failure modes include blocked filters, fouled coils and refrigerant undercharge. Each checkpoint takes pass, fail, or N/A, and a failed item stays open until the fix is verified.
It expects filter photo, coil photo and gauge reading on failed or critical items, so findings rest on proof rather than memory. Records support ASHRAE 180, F-Gas and TM44, and every photo, note, and sign-off stays attached to the inspection instead of living in chat threads.
It checks filter condition, coil cleanliness, refrigerant readings and damper operation across education sites. The round exists to confirm HVAC plant delivers designed airflow, filtration, and refrigerant integrity. It prioritises failure modes such as blocked filters, fouled coils and refrigerant undercharge. HVAC engineers record pass, fail, or N/A on each item, capture photo evidence on anything that needs proof, and assign corrective actions with owners and due dates. Evidence expectations include filter photo, coil photo and gauge reading. A failed item stays open until the fix is verified, and it runs offline so a weak signal never costs a round. Run in InspectWrk, every finding is timestamped and exports as a single education report aligned to ASHRAE 180, F-Gas and TM44.

Education building handover readiness: classrooms, labs, and MEP.

Library snagging: finishes, lighting, power, data, and environmental controls.

School classroom snagging: finishes, lighting, AV, and accessibility.

Lecture hall snagging: AV, acoustics, seating, and MEP.