Use this escalator preventive maintenance checklist to check escalator identification and condition, steps and treads, handrails, comb plates and skirt panels, drive system, chains and brakes, and safety devices, recording pass, fail, or N/A and capturing a photo on anything that needs proof.
8 sections24 questions12 to 23 minutesFree
Photo Added
Photo Added
Photo Added8 sections · 24 questions · 12 to 23 minutes · Free
Record the escalator unit number, location, and rise.
Confirm the escalator matches the asset register and PM schedule.
Confirm the unit is isolated and safe to work on per site procedure.
Inspect steps and treads for cracks, wear, and missing cleats.
Check the step-to-skirt and step-to-comb clearances.
Confirm steps run level and track correctly.
Check handrail condition, tension, and speed against the steps.
Inspect handrail entry guards and inlets.
Confirm the handrail runs smoothly with no snagging.
Inspect comb plates for damaged or missing teeth.
Check skirt panels for damage and correct clearance.
Confirm skirt brushes or deflectors are intact where fitted.
Inspect the drive system, step chains, and sprockets for wear and tension.
Confirm the main brake and any auxiliary brake operate and hold.
Check lubrication of chains and drive components.
Test emergency stop buttons at top and bottom.
Confirm comb, skirt, step, and handrail safety switches trip correctly.
Verify the unit stops and cannot restart until reset.
Check step demarcation lighting, landing lighting, and signage.
Note excessive noise or vibration during a run.
Confirm balustrade and decking are secure.
Confirm the truss pit and components are clean and clear of debris.
Capture a photo of every failed item as evidence.
Raise a corrective action with an owner and due date, and record the maintenance.
Three steps, about 12 to 23 minutes.
Section by section, one check at a time.
Tap Fail, add a photo, assign who fixes it.
The report is ready the moment you finish.
Paper for a one-off check. The app when every finding needs fixing.
Branded checklist
Customize with your logo and company details.
Quick answer
An escalator preventive maintenance checklist is the planned maintenance verification used to confirm escalators and moving walks carry passengers safely with sound steps, combs, and safety devices that facilities management teams use to check the key inspection points, assign owners to any failures, and close them with photo proof. Completed in InspectWrk, it is timestamped, works offline, and exports as an audit-ready facilities management report for OSHA, ISO 41001 and fire NOC and lift license requirements.
An escalator preventive maintenance checklist is the planned maintenance verification used to confirm escalators and moving walks carry passengers safely with sound steps, combs, and safety devices that facilities management teams use to check escalator identification and condition, steps and treads, handrails, comb plates and skirt panels, drive system, chains and brakes, and safety devices, capture photo evidence, and track corrective actions to closure. Its job is to confirm escalators and moving walks carry passengers safely with sound steps, combs, and safety devices. Service an escalator end to end: steps and treads, handrails, comb plates, drive system, chains, brakes, skirt panels, safety sensors, emergency stop, lighting and signage, lubrication, and noise or vibration, with cleaning and maintenance records.
Lift and escalator engineers and facilities teams still miss damaged steps or wide gaps, broken comb teeth and handrail speed mismatch when rounds are ticked without step and comb photo, emergency stop test note and handrail photo.
Without a single inspection record, teams reconstruct the evidence from phones instead of proving OSHA, ISO 41001 and fire NOC and lift license requirements readiness.
It helps centre managers and supervisors keep facilities management work consistent, safe, and auditable, with the evidence needed for OSHA, ISO 41001 and fire NOC and lift license requirements:
A complete escalator preventive maintenance checklist works through escalator identification and condition, steps and treads, handrails, comb plates and skirt panels, drive system, chains and brakes, and safety devices, then records inspection context, scored checkpoints, and evidence with corrective actions:
Record where and when the inspection runs:
Define what each checkpoint verifies and how results are scored:
Make every finding traceable and actionable:
Follow these steps to run the escalator preventive maintenance checklist:
See how this checklist fits into Facility maintenance software.
This checklist runs as a mobile inspection app that works fully offline on site, with AI-powered defect detection on every photo. To see it on your own workflows, talk to our team.
Submit an inspection and AI writes the PDF report and Excel sheet for you. No admin, no waiting.
Your inspector takes a photo of any asset or defect. AI reads it and fills the inspection form automatically.
No typing. No manual entry.
Inspectors speak their observations in any language. AI transcribes and fills the form in real time.
Completely hands-free in the field.
The moment an inspection is submitted, AI summarises the findings and builds a branded PDF report and an Excel sheet for you.
No manual reporting. No copy-paste.
InspectWrk integrates with the tools your team already uses, including Zoho, Microsoft 365, and SAP.
No double entry.
Your operations team sees completion rates, open issues, and compliance scores across all sites in real time.
No chasing updates.
See which checklists your team has in progress across every site, jump into the same inspection with one tap, and keep field, supervisor, and back-office views in sync without sending screenshots on WhatsApp.
Every team reports differently. Build the report your operations, quality, or compliance leads actually want to read, share it as a branded PDF, and schedule delivery to the stakeholders who need it.
See completion, pass rate, and recurring findings across every checklist and every site, without pulling spreadsheets together at the end of the month.
See this checklist running on your own sites in a 30-minute demo.
Book a Free DemoIt is scoped to the preventive maintenance cadence and controls that centre managers, facility managers, AFM and CE teams, operations directors run, not a one-off handover walk. It prompts escalator identification and condition, steps and treads, handrails, comb plates and skirt panels, drive system, chains and brakes, and safety devices, watching for damaged steps or wide gaps, broken comb teeth and handrail speed mismatch, records pass, fail, or N/A with step and comb photo, emergency stop test note and handrail photo on critical items, and raises corrective actions with owners before sign-off. Run in InspectWrk, the record is timestamped and rolls into trend reports so repeat failures surface before the next audit.
They work through each checkpoint to confirm escalators and moving walks carry passengers safely with sound steps, combs, and safety devices, confirm the required controls are in place, and capture step and comb photo, emergency stop test note and handrail photo on anything that fails or needs proof. Priority failure modes include damaged steps or wide gaps, broken comb teeth and handrail speed mismatch. Each checkpoint takes pass, fail, or N/A, and a failed item stays open until the fix is verified.
It expects step and comb photo, emergency stop test note and handrail photo on failed or critical items, so findings rest on proof rather than memory. Records support OSHA, ISO 41001 and fire NOC and lift license requirements, and every photo, note, and sign-off stays attached to the inspection instead of living in chat threads.
The escalator preventive maintenance checklist covers escalator identification and condition, steps and treads, handrails, comb plates and skirt panels, drive system, chains and brakes, and safety devices. On each checkpoint, centre managers record pass, fail, or N/A, add a photo on anything that needs proof, and raise a corrective action with an owner and due date. Run in InspectWrk, the inspection is timestamped, traceable to whoever completed it, and exports as a single facilities management report aligned to OSHA, ISO 41001 and fire NOC and lift license requirements.

Standard site-level inspections for construction, safety, and compliance.

Complete work orders with checklist items, photos, and sign-off.

Inspect assets and equipment: condition, location, photos, and maintenance history.

Run the Maintenance Checklist on the InspectWrk app to capture photo evidence per finding and generate audit-ready reports.