Take a Photo. AI Fills the Form.
Your inspector takes a photo of any asset or defect. AI reads it and fills the inspection form automatically.
No typing. No manual entry.
Use this switchgear preventive maintenance checklist to work through switchgear identification and safety, enclosure and housekeeping, busbars and connections, circuit breakers and disconnects, insulation and grounding, and interlocks, protective devices and relays, logging issues with photos and notes and assigning corrective actions before sign-off.
8 sections23 questions14 to 26 minutesFree
Photo Added
Photo Added
Photo Added8 sections · 23 questions · 14 to 26 minutes · Free
Record the switchgear tag, location, rating, and lineup identification.
Confirm the switchgear matches the asset register and PM schedule.
Confirm the section is de-energised, isolated, and safe to work on per procedure.
Inspect the enclosure, doors, and covers for damage and secure fit.
Confirm the switchroom is clean, dry, and clear of stored material.
Check access, barriers, and warning signage are in place.
Inspect busbars and joints for discoloration, pitting, and looseness.
Check terminals and connections for tightness and heat damage.
Confirm cable terminations and supports are secure.
Operate circuit breakers and disconnects to confirm correct action.
Inspect contacts and mechanisms for wear and arcing where accessible.
Confirm ratings, settings, and labeling are correct.
Inspect insulation, barriers, and standoffs for cracks and tracking.
Confirm grounding and bonding connections are intact and secure.
Confirm mechanical and electrical interlocks operate correctly.
Check protective relays and devices are set and functional.
Verify indication and metering read correctly.
Record signs of overheating at joints and connections.
Inspect for corrosion on the enclosure and internal components.
Clean components per procedure and confirm ventilation is clear.
Complete functional checks and return the section to service safely.
Capture a photo of every failed item as evidence.
Raise a corrective action with an owner and due date, and record the maintenance.
Three steps, about 14 to 26 minutes.
Section by section, one check at a time.
Tap Fail, add a photo, assign who fixes it.
The report is ready the moment you finish.
Paper for a one-off check. The app when every finding needs fixing.
Branded checklist
Customize with your logo and company details.
Quick answer
A switchgear preventive maintenance checklist is the planned maintenance verification used to confirm switchgear can isolate safely with interlocks, protection, and insulation intact that facilities management teams use to check the key inspection points, assign owners to any failures, and close them with photo proof. Completed in InspectWrk, it is timestamped, works offline, and exports as an audit-ready facilities management report for OSHA, ISO 41001 and fire NOC and lift license requirements.
A switchgear preventive maintenance checklist is the planned maintenance verification used to confirm switchgear can isolate safely with interlocks, protection, and insulation intact that facilities management teams use to check switchgear identification and safety, enclosure and housekeeping, busbars and connections, circuit breakers and disconnects, insulation and grounding, and interlocks, protective devices and relays, capture photo evidence, and track corrective actions to closure. Its job is to confirm switchgear can isolate safely with interlocks, protection, and insulation intact. Service an electrical switchgear assembly: enclosure, busbars, circuit breakers, disconnects, terminals and connections, grounding, insulation, interlocks, protective devices and relays, signs of overheating, and corrosion, with cleaning, functional checks, and maintenance records.
HV/LV technicians and electrical engineers still miss failed interlock, relay in alarm and tracking on insulation when rounds are ticked without relay status photo, mechanism cycle note and IR scan.
Without a single inspection record, teams reconstruct the evidence from phones instead of proving OSHA, ISO 41001 and fire NOC and lift license requirements readiness.
It helps centre managers and supervisors keep facilities management work consistent, safe, and auditable, with the evidence needed for OSHA, ISO 41001 and fire NOC and lift license requirements:
A complete switchgear preventive maintenance checklist works through switchgear identification and safety, enclosure and housekeeping, busbars and connections, circuit breakers and disconnects, insulation and grounding, and interlocks, protective devices and relays, then records inspection context, scored checkpoints, and evidence with corrective actions:
Record where and when the inspection runs:
Define what each checkpoint verifies and how results are scored:
Make every finding traceable and actionable:
Follow these steps to run the switchgear preventive maintenance checklist:
See how this checklist fits into Facility maintenance software.
This checklist runs as a mobile inspection app that works fully offline on site, with AI-powered defect detection on every photo. To see it on your own workflows, talk to our team.
Submit an inspection and AI writes the PDF report and Excel sheet for you. No admin, no waiting.
Your inspector takes a photo of any asset or defect. AI reads it and fills the inspection form automatically.
No typing. No manual entry.
Inspectors speak their observations in any language. AI transcribes and fills the form in real time.
Completely hands-free in the field.
The moment an inspection is submitted, AI summarises the findings and builds a branded PDF report and an Excel sheet for you.
No manual reporting. No copy-paste.
InspectWrk integrates with the tools your team already uses, including Zoho, Microsoft 365, and SAP.
No double entry.
Your operations team sees completion rates, open issues, and compliance scores across all sites in real time.
No chasing updates.
See which checklists your team has in progress across every site, jump into the same inspection with one tap, and keep field, supervisor, and back-office views in sync without sending screenshots on WhatsApp.
Every team reports differently. Build the report your operations, quality, or compliance leads actually want to read, share it as a branded PDF, and schedule delivery to the stakeholders who need it.
See completion, pass rate, and recurring findings across every checklist and every site, without pulling spreadsheets together at the end of the month.
See this checklist running on your own sites in a 30-minute demo.
Book a Free DemoIt is scoped to the preventive maintenance cadence and controls that centre managers, facility managers, AFM and CE teams, operations directors run, not a one-off handover walk. It prompts switchgear identification and safety, enclosure and housekeeping, busbars and connections, circuit breakers and disconnects, insulation and grounding, and interlocks, protective devices and relays, watching for failed interlock, relay in alarm and tracking on insulation, records pass, fail, or N/A with relay status photo, mechanism cycle note and IR scan on critical items, and raises corrective actions with owners before sign-off. Run in InspectWrk, the record is timestamped and rolls into trend reports so repeat failures surface before the next audit.
They work through each checkpoint to confirm switchgear can isolate safely with interlocks, protection, and insulation intact, confirm the required controls are in place, and capture relay status photo, mechanism cycle note and IR scan on anything that fails or needs proof. Priority failure modes include failed interlock, relay in alarm and tracking on insulation. Each checkpoint takes pass, fail, or N/A, and a failed item stays open until the fix is verified.
It expects relay status photo, mechanism cycle note and IR scan on failed or critical items, so findings rest on proof rather than memory. Records support OSHA, ISO 41001 and fire NOC and lift license requirements, and every photo, note, and sign-off stays attached to the inspection instead of living in chat threads.
The switchgear preventive maintenance checklist covers switchgear identification and safety, enclosure and housekeeping, busbars and connections, circuit breakers and disconnects, insulation and grounding, and interlocks, protective devices and relays. On each checkpoint, centre managers record pass, fail, or N/A, add a photo on anything that needs proof, and raise a corrective action with an owner and due date. Run in InspectWrk, the inspection is timestamped, traceable to whoever completed it, and exports as a single facilities management report aligned to OSHA, ISO 41001 and fire NOC and lift license requirements.

Standard site-level inspections for construction, safety, and compliance.

Complete work orders with checklist items, photos, and sign-off.

Inspect assets and equipment: condition, location, photos, and maintenance history.

Run the Maintenance Checklist on the InspectWrk app to capture photo evidence per finding and generate audit-ready reports.